Main items of work |
|
Technical specifications of items |
Unit |
First: aggradations, digging, filling works for ground works
|
1 |
Location aggradations 25cm including digging, filling according technical specifications |
M 2 |
|
2 |
Digging work for ground works in any kind of earth with required depth |
M 3 |
|
3 |
Filling with earth obtained from digging, aggradations according technical specification |
M 3 |
|
4 |
Filling with earth from outside, aggradations according technical specification |
M 3 |
|
5 |
Transport of residues |
M 2 |
|
Second: ground bases (bases, poles, beams) |
1 |
Supply and mixing normal concrete consisting of 0.8 m 3 small stones (pebbles)+1.0 m 3 sand +250 Kg cement with thickness 15 cm under ground bases |
M 2 |
|
2 |
Supply and casting of reinforced concrete consisting of 0.8 m 3 pebbles (small stones)+ 0.40 m 3
sand + 350 Kg cement for each m 3 for ground works for poles. |
M 3 |
|
3 |
Supply and painting hot bitumen two layers for bases, walls, poles -rate including roof cleaning by coil brush |
M 2 |
|
4 |
Stone filling under the building ground from line stone of thickness 15 cm |
M 2 |
| |
5 |
Concrete grounds of building with thickness 10 cm of normal concrete as concrete for bases bottom |
M 2 |
|
| Third: reinforced concrete for poles |
1 |
Supply and casting of reinforced concrete from mixture as bases concrete according drawings and specifications |
M 3 |
| |
2 |
Supply and casting of reinforced concrete for walls from mixture of bases concrete |
M 3 |
| |
|
|
|
| Fourth: reinforced concrete for roofs and beans |
1 |
Supply and casting reinforced concrete for stairs of mixture of bases concrete |
M 3 |
| |
2 |
Supply and casting concrete roofs from concrete as bases concrete and use of bricks 25 cm without allowance for beans and some tiles |
M 2 |
| |
|
|
|
| Fifth: building works + tie beams and beans for doors and windows |
1 |
Supply and building of cement bricks with thickness 10,15,20,25 cm with mortar consisting of 250 Kg cement for 1 m 3 of sand and from cement bricks according maps |
M 3 |
| |
2 |
Supply and casting reinforced concrete for beans from mixture the same as bases concrete |
M 3 |
| |
3 |
To supply and casting reinforced concrete from mixture same as base concrete |
M 3 |
| |
4 |
To supply and erect buildings of stone blocks with mortar same as mixture of cement block |
M 3 |
| |
| Sixth: interior plastering |
|
Remarks: general spray plastering to be made for all roofs to be plastered by mortar which consist of 450 Kg cement with 1 m 3 sand according technical specifications and installation of metal nets between buildings and concrete |
|
| |
1 |
To supply and make hard plaster for walls and internal roofs with mortar which consist of 300 Kg cement + 2/3 m 3 sand |
M 2 |
|
|
|
|
| Seventh: sanitary works including insulating layer |
1 |
To supply and make insulating layer for roofs for humidity from heated asphalt and kwalina of thickness 1.5 cm including gap of height not less than 25 cm without allowance for bathrooms, kitchens and roof of building |
M 2 |
| 2 |
To supply and install colored china washing basin and base not less than 48×45 cm for each flat and include water mix, copper plated siphon, chrome plated valve diameter ½ inch, plastic connection diameter 35/43, length about 80 cm and all requirements according specifications and drawings |
Number |
| 3 |
Same previous item with dimensions not less than 35×50 cm and without base for each flat |
Number |
| 4 |
To supply and install colored pottery double washing basin for each flat and complete filter size 45×120 cm, water mix, two siphons 2 water valves (hot, cold) diameter ½ inch from copper and chrome plated- connection PVC 50/60 length 80 cm according specifications and drawings |
Number |
| 5 |
To supply and install 2 complete colored china toilet sets, valve diameter ½ inch- copper plated plastic connection 110/114 length about 1 meter and all requirements according specifications and drawings for each flat |
Number |
| 6 |
To supply and install "washing basin" pottery plated with china colored for each flat with water mix, siphon, valve ½ all in copper plated chrome, plastic connection 1.5 inch length about 80 cm and all requirements according drawings and specifications |
Number |
|
7 |
To supply and install 2 complete washers for each flat- copper valve chrome plated with all requirements according drawings |
Number |
| 8 |
To supply and install bath basin china plated according required color 170×70 cm for each flat with thickness 10 cm around the basin siphon and mix with shower and valve diameter 0.500 m and pottery soap holder 15×20 cm, plastic connection diameter 2 inches and all requirements according specifications and drawings |
Number |
| 9 |
To supply and install 2 chrome steel holders for each flat according specifications and technical conditions |
Number |
10 |
To supply and install kitchen marble 120×45×3cm for each flat with all requirements according specifications |
Number |
| 11 |
To supply and install 5 plastic ground siphons diameter 5 inches for each flat including plastic connection 50/60 mm, length 80 cm with all requirements according technical specifications and drawings |
Number |
| 12 |
To supply and install electric water heater 80 liters capacity for each flat, inclusive of 2 valves 0.500 and electric connection according drawings and specifications |
Number |
| 13 |
Same as item 12, but capacity 50 liters |
Number |
| 14 |
To supply and install plastic tubes 35/43 mm including all welding, packing, concrete required according specifications, drawings and technical conditions |
L. m |
| 15 |
Same as item 14 but pipes diameter 50/60 |
L. m |
| 16 |
To supply and install water pipes ¾ inches of P.P.R including all connection pieces and requirements according drawings and technical specification for cold water |
L. m |
| 17 |
Same as previous item but pipes with diameter ¾ for hot water |
L. m |
| 18 |
To supply and install steel water pipes diameter 1 inch grade (b) will all connections and fixing on wall, painting with 2 layers primer and final layer with required color, for the purpose of connection of main tank to each flat |
L. m |
| 19 |
To supply and install pipes as in previous item for water but with diameter 2 inches to supply upper tanks of the building |
L. m |
| 20 |
To supply and install 3 valves of P.P.R diameter ¾ inches for each flat with all requirements according technical specifications and drawings |
Number |
| 21 |
Same as previous item but 2 valves bronze, diameter 1 inch for the building |
Number |
| 22 |
Same as previous item but bronze valve diameter 2 inches with 5 for the building |
Number |
| 23 |
To supply and install plastic pipes pressure 10 bar diameter 3 inches on the wall with all requirements, fixing on wall, paints with required color according drawing and specifications |
L. m |
| 24 |
Same as previous item but pipes diameter 4 inches on wall for sewage |
L. m |
| 25 |
Same as previous item but pipes diameter 4×0.25 for rain water outfall |
L. m |
| 26 |
To supply and install ventilator for each sewage outfall pipe |
|
| |
a) Diameter 3 inches |
Number |
| |
b) Diameter 4 inches |
Number |
| 27 |
To supply and install system (Gregory) diameter 4 for rain water outfall, charges include paints, mortar and all requirements according drawings and specifications 5 for each building |
Number |
| 28 |
To supply and install (galtrab) from pottery with steel cover including digging, filling, concrete, cement, plastering and all requirements according specifications and drawings- 8 for each building and the ground floor separately |
Number |
| 29 |
To supply and install plastic pipes diameter 6 inches under ground including digging, filling concrete, covering pipes and all requirements according drawings |
L. m |
| 30 |
Same as previous item but pipes diameter 8 inches |
L. m |
| 31 |
To supply and install case for meters from sheets thickness 16/1 for the building which consist of 8 flats including supplying and installing 8 meters 0.75 complete with valves and requirements of same diameter as well as main valve, connections and all requirements according specifications and drawings |
Number |
| 32 |
To supply and install manhole with internal diameter 60×60 cm roof, ground and walls from normal concrete and cement plastering, excavation, filling and cover of cast iron weighing 60 Kg and all requirements according specifications and drawings 4 for the building |
Number |
| 33 |
Same as previous item but manhole 80×80 cm and depth 1.50 m- 3 for the building |
Number |
| 34 |
To supply and install sunk pump capacity 3 Hp for lifting water to upper tank including connection with pipes, price including connection of operating keys, meters, float for keeping water level in the ground tank as well as all requirements according specifications and drawings |
Number |
| 35 |
To supply and install connections of ground concrete tanks which consist of:-
Entrance galvanized pipe diameter 2 with paints
Exit galvanized pipe diameter 2 with paints
Valve diameter 2 inches
Normal float to be installed at the end of the supply line
Electric float to keep water level for the pump
Ventilators diameter 1.5
Opening for cleaning with galvanized painted pipes diameter 1.5
1 galvanized sheet cover with all connections, work, mortar according specifications and drawings |
Lump sum |
| 36 |
To supply and install connections of upper concrete tanks which consist of:-
2 valves 2 inches
1 valve 1.5 inch
1 electric float
Ventilation pipe
5 double cast iron
1 aluminum cover for the tank
1 ladder for use on building roof to tank
1 cleaning pipe
With connection of electric circuit for the float and all requirements according technical specifications |
Lump sum |
| 37 |
To supply and install water mixer for washing machine diameter 0.5 including connection pieces according technical specifications for each flat |
Number |
| 38 |
To supply and install PVC pipes diameter 2 inches pressure 10 bar for rain water outfall in balconies fixing pipes on wall, painting and all requirements according technical specifications |
Number |
| 39 |
Construction of dam in building ground with internal measurement 2×3×6 according maps including digging, filling, plastering, ceramic for the tank and cover from galvanized sheets, lean concrete under reinforced concrete of tank floor and construction of room 1.0×1.0×1.0 for the sunk pump and opening for feeding pipes and all requirements according technical specifications, drawing and engineer's instructions |
Lump sum |
| 40 |
Same as previous item but upper tank and dimensions according maps |
Lump sum |
| 41 |
To construct analysis tank for each building (5×10×3) work includes digging in any kind of earth, filling back, transport of residues outside location, concrete for base, beans, poles, roofs and cover from cast iron weighing 125 Kg |
|